Inicio Empresa Novedades Productos Biblioteca Donde

 

 

   PRODUCTOS

> Contactores
> Guardamotores
> Variadores
> Controladores P.L.C
      >> EH-Micro
      > EH-150
      > Serie-H
      > EH-WD10DR
> Interfaces HMI
> Botoneras
> Arrancadores Suaves
> Aparatos para CC

>> Controladores Lógicos Programables PLC >> EH-Micro >> Especificaciones >> Spec01

10 point / 14 point / 23 point / 28 point type CPU Specifications

Item 10 point type 14 point type 23 point type 28 point type
Control specifications CPU 32-bit RISC processor
Processing system Stored program cyclic system
Processing
Speed
Basic instructions 0.9 µs / instruction
Application instructions Several 10 µs / instruction
User program memory 3 k steps max. (FLASH memory)
Operation processing specifications Instruction language Basic instructions 39 types such as LD, LDI, AND, ANI, OR, ORI, ANB, ORB, OUT, MPS, MRD, MPP, etc.
Arithmetic instructions
Application instructions
62 types (arithmetic, application, control, FUN command etc.)
Ladder Basic instructions 39 types, such as
Basic ladder
Arithmetic instructions
Application instructions
62 types (arithmetic, application, control, FUN command etc.)
I/O processing specifications External I/O I/O processing system Refresh processing
Maximum number of points 10 points 126 points 135 points 140 points
Internal output Bit 1,984 points (R0 to R7BF)
Word 4,096 words (WR0 to WRFFF)
Special Bit 64 points (R7C0 to R7FF)
Word 512 words (WRF000 to WRF1FF)
Bit / Word shared 16,384 points, 1,024 words
(M0 to M3FFF, WM0 to WM3FF)
Timer counter Number of points 256 points (TD+CU) *1
Timer set value 0 to 65,535, timer base 0.01 s, 0.1 s, 1 s
(0.01s has maximum 64 points *2)
Counter set value 1 to 65,535 times
Edge detection 512 points (DIF0 to DIF511:Decimal)
+ 512 points (DFN0 to DFN511:Decimal)
Peripheral equipment Program system Instruction language, ladder diagram
Peripheral unit Programming software
(LADDER EDITOR DOS version/Windows® version, Pro-H)
Instruction language programmer and form graphic display programmer cannot be used.
Maintenance functions Self-diagnosis PLC error (LED display): Microcomputer error, watchdog timer error, memory error, program error, system ROM/RAM error, scan time monitoring, battery voltage low detection, etc.
*1
The same numbers cannot be used with the timer counter.
*2
Only timers numbered 0 to 63 can use 0.01 s for their timer base.