20/40/64 point type Input / Output Specifications
High Speed Counter
| |
Single |
2-phase |
| Choices for counter input channels |
X0, X2, X4, X6 |
Use X0 and X2 in pair / Use X4 and X6 in pair |
| Input voltage |
ON |
18 V |
| OFF |
5 V |
| Width of count pulse |
10 µs |
17 µs |
| Maximum count frequency |
100 kHz |
60 kHz |
| Count register |
16 bits / 32 bits (depend on operation mode) |
| Coincidence output |
Possible (or assigned as standard output) |
| ON/OFF-preset |
Possible (or assigned as standard output) |
| Upper/lower limit setting |
Impossible (16 bits counter : ring counter ... 0 to 65,535) (32 bits counter : ring counter ... 0 to 4,294,967,295) |
| Pre-load / Strobe |
Possible (or assigned as standard input) |
Pulse train output / PWM output
| Item |
Specification |
| Available outputs |
Y100-Y103 (optional) |
| Load voltage |
12/24 V |
| Minimum load current |
1mA |
| PWM max. output frequency |
65,535 Hz |
| Pulse train max. output frequency |
65,535 Hz |
- *
- Please do not use a relay output type as a pulse output.
Interrupt Input Specifications
| Input that can be used |
X1.X3.X5.X7 (by user settings) |
| Input voltage |
ON |
18 V |
| OFF |
5 V |
|