L700: Rango
 Clase 400V Trifásico (3x380V)
 
| Modelo L700- | 
110 
HFF  | 
150 
HFF  | 
185 
HFF  | 
220 
HFF  | 
300 
HFF  | 
370 
HFF  | 
450 
HFF  | 
550 
HFF  | 
750 
HFF  | 
900 
HFF  | 
1100 
HFF  | 
1320 
HFF  | 
1600 
HFF  | 
| 
Clase de protección | 
IP20 | 
IP00 | 
| Motor (4-polos, kW(HP) | 
11(15) | 
15(20) | 
18.5(25) | 
22(30) | 
30(40) | 
37(50) | 
45(60) | 
55(75) | 
75(100) | 
90(125) | 
110(150) | 
132(175) | 
160(220) | 
| 
Rangos de salida  | 
Potencia nominal (KVA) | 
400V | 
15.2 | 
20.9 | 
25.6 | 
30.4 | 
39.4 | 
48.4 | 
58.8 | 
72.7 | 
93.5 | 
110.8 | 
135 | 
159.3 | 
200.9 | 
| 480V | 
18.2 | 
24.1 | 
30.7 | 
36.5 | 
47.3 | 
58.1 | 
70.6 | 
87.2 | 
112.2 | 
133   | 
162.1 | 
191.2 | 
241.1 | 
| 
Corriente nominal de salida (A) | 
22 | 
29 | 
37 | 
43 | 
57 | 
70 | 
85 | 
105 | 
135 | 
160 | 
195 | 
230 | 
290 | 
| 
Capacidad de sobrecarga  (corriente de salida) | 
120%,60sec | 
| 
Tensión nominal de salida | 
Trifásica 380 a 480V (correspondiendo a la tensión de entrada) | 
| 
Rango de entrada | 
Tensión nominal de entrada (V) | 
Trifásica  380 a 480V+10%, -15%, 50/60Hz±5% | 
| 
Frenado | 
Frenado dinámico (corto tiempo) | 
Circuito BRD integrado (resistor opcional ) | 
Unidad externa de frenado dinámico (opción) | 
| 
Tamaño mínimo del resistor  (Ω) | 
35 | 
35 | 
24 | 
24 | 
20 | 
— | 
| Vibración | 
5.9m/s2(0.6G), 10-55Hz | 
2.9m/s2(0.3G), 10-55Hz | 
| Filtro EMC Integrado  | 
Integrado (EN61800-3 categoría C3) | 
| 
Reactor de Fase-cero | 
Integrado  | 
| 
Peso en kg (lbs.) | 
6(13.2) | 
6(13.2) | 
14(30.8) | 
14(30.8) | 
14(30.8) | 
22(48.4) | 
30(66) | 
30(66) | 
30(66) | 
55(121) | 
55(121) | 
70(154) | 
70(154) | 
  
  Clase 200V Monofásico (3x220V)
 
| Modelo L700- | 
110LFF | 
150LFF | 
185LFF | 
220LFF | 
300LFF | 
370LFF | 
450LFF | 
550LFF | 
750LFF | 
| 
Clase de protección | 
IP20 | 
| Motor (4-polos, kW(HP) | 
11(15) | 
15(20) | 
18.5(25) | 
22(30) | 
30(40) | 
37(50) | 
45(60) | 
55(75) | 
75(100) | 
| 
Rangos de salida  | 
Potencia nominal (KVA) | 
200V | 
15.2 | 
20.0 | 
26.3 | 
29.4 | 
39.1 | 
49.5 | 
59.2 | 
72.7 | 
93.5 | 
| 240V | 
18.2 | 
24.1 | 
31.5 | 
35.3 | 
46.9 | 
59.4 | 
71.0 | 
87.2 | 
112.2 | 
| 
Corriente nominal de salida (A) | 
44 | 
58 | 
73 | 
85 | 
113 | 
140 | 
169 | 
210 | 
270 | 
| 
Capacidad de sobrecarga  (corriente de salida) | 
120%,60sec | 
| 
Tensión nominal de salida | 
Trifásica  200 a 240V (correspondiendo a la tensión de entrada) | 
| 
Rango de entrada | 
Tensión nominal de entrada (V) | 
Trifásica a 240V+10%, -15%, 50/60Hz±5% | 
| 
Frenado | 
Frenado dinámico (corto tiempo) | 
Circuito BRD integrado (resistor opcional ) | 
Unidad externa de frenado dinámico (opción) | 
| 
Tamaño mínimo del resistor  (Ω) | 
10 | 
10 | 
7.5 | 
7.5 | 
5 | 
- | 
| Vibración | 
5.9m/s2(0.6G), 10~55Hz | 
2.9m/s2(0.3G), 10~55Hz | 
| Filtro EMC Integrado  | 
Integrado  (EN61800-3 categoría C3) | 
| 
Reactor de Fase-cero | 
Integrado | 
| 
Peso en kg (lbs.) | 
6(13.2) | 
6(13.2) | 
14(30.8) | 
14(30.8) | 
14(30.8) | 
22(48.4) | 
30(66) | 
30(66) | 
43(94.6) |